CerroWire CerroMax™ Nonmetallic Sheathed Indoor Copper Building Cable (12 ft. Yellow)
Applications
For use primarily in residential wiring, including branch circuits for outlets, switches, etc.
May be installed in both exposed and concealed work in normally dry locations. May be installed in air voids of masonry block or tile walls where these walls are not subject to excessive moisture or dampness. May be installed in locations with temperatures up to 90°C, but with the ampacity limited to that of 60°C conductors. Added Circuit: For use primarily in residential wiring for branch circuits supplying outlets located in bedrooms and other areas. Has two separated neutrals so one cable can be used to run two circuits when sharing of a neutral is not allowed.
- Branch circuit wiring
- Ceiling fans
- Dry locations only
- Receptacles
- Residential
Conductors
Solid conductors
- Soft, uncoated copper per ASTM B3
Stranded conductors
- Uncoated copper per ASTM B3 and ASTM B8
Insulation
Color-coded PVC (polyvinyl chloride) rated 90°C dry with nylon (polyamide) covering
(Where included, additional neutral will have a red stripe for identification.)
Jacket
PVC (polyvinyl chloride) jacket applied over the complete assembly
14-2 AWG: White jacket; 14-3 AWG: Light Blue
12-2 AWG: Yellow jacket; 12-3 AWG: Purple
10-2 AWG: Orange jacket; 10-3 AWG: Pink
8 AWG: Black jacket
Custom jacket colors available with minimum order quantities
Industry Standards
Standards:
UL 719: E9810
UL 83: E15119
ASTM B3
ASTM B8
*It is the sole responsibility of the end user to determine suitability of this product for its intended end use and application.
Assembly
PVC-jacketed cable with two-, three- or four-circuit conductors and an equipment grounding conductor. Intended for use in accordance with the National Electrical Code®.
Two-conductor constructions have the insulated conductors laid parallel. The ground wire is wrapped with fire-retardant paper and laid parallel between the insulated conductors. The entire construction is wrapped with a paper separator before applying the jacket.
Three (or more) conductor constructions have the insulated conductors twisted together or laid parallel to each other. Ground wire is wrapped with paper and twisted together or laid parallel to the insulated conductor.
Surface Print
Sample: NM-B 14-2 W/G CerroMax-I (UL)
(Additional information may be included.)
Colors
- White: 14/2 awg\
- NMB Light Blue: 14/3 awg
- Yellow: 12/2 awg
- NMB Purple: 12/3 awg
- Orange: 10/2 awg
- NMB Pink: 10/3 awg
- Black: 4, 6, 8 awg